Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 72
Filtrar
1.
AJR Am J Roentgenol ; 2024 Feb 28.
Artigo em Inglês | MEDLINE | ID: mdl-38415576

RESUMO

Contrast-enhanced ultrasound (CEUS) is distinguished from CT and MRI by the use of microbubble ultrasound contrast agents (UCAs) with intravascular blood pool distribution. When performing CEUS, low-intensity ultrasound allows real-time tissue subtraction imaging, whereas high-intensity ultrasound leads to microbubble destruction, enabling visualization of the contrast inflow pattern. CEUS has exceptional contrast resolution that enables the detection of even minimal blood flow, achieving very high NPV for ruling out vascular perfusion and providing high frame rates in the evaluation of tissue perfusion dynamics. UCAs undergo hepatic metabolism and pulmonary clearance, ensuring safety in patients with renal impairment. CEUS excels in distinguishing solid from cystic renal masses, with higher sensitivity than CT or MRI for detection of lesion enhancement. CEUS can aid the further characterization of both solid and cystic lesions and may have particular applications in the surveillance of cystic masses and surveillance after renal cell carcinoma ablation. This review describes the use of CEUS to help characterize indeterminate renal masses, based on the authors' institutional experience. The article highlights key differences between CEUS and CT or MRI, and provides practical insights for performing and interpreting CEUS of renal masses.

3.
Clin J Am Soc Nephrol ; 17(6): 827-834, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-35383043

RESUMO

BACKGROUND AND OBJECTIVES: Total kidney volume is a validated prognostic biomarker for autosomal dominant polycystic kidney disease. Total kidney volume by magnetic resonance imaging (MRI) and manual segmentation is considered the "reference standard," but it is time consuming and not readily accessible. By contrast, three-dimensional (3D) ultrasound provides a promising technology for total kidney volume measurements with unknown potential. Here, we report a comparative study of total kidney volume measurements by 3D ultrasound versus the conventional methods by ultrasound ellipsoid and MRI ellipsoid. DESIGN, SETTING, PARTICIPANTS, & MEASUREMENTS: This single-center prospective study included 142 patients who completed a standardized 3D ultrasound and MRI. Total kidney volumes by 3D ultrasound and ultrasound ellipsoid were compared with those by MRI. We assessed the agreement of total kidney volume measurements by Bland-Altman plots and misclassification of the Mayo Clinic imaging classes between the different imaging methods, and we assessed prediction of Mayo Clinic imaging classes 1C-1E by average ultrasound kidney length >16.5 cm. RESULTS: Compared with MRI manual segmentation, MRI ellipsoid, 3D ultrasound, and ultrasound ellipsoid underestimated total kidney volume (mean difference: -3%, -9%, and -11%, respectively), with Mayo Clinic imaging classes misclassified in 11%, 21%, and 22% of patients, respectively; most misclassified cases by MRI ellipsoid (11 of 16), 3D ultrasound (23 of 30), and ultrasound ellipsoid (26 of 31) were placed into a lower Mayo Clinic imaging class. Predictions of the high-risk Mayo Clinic imaging classes (1C-1E) by MRI ellipsoid, 3D ultrasound, and ultrasound ellipsoid all yielded high positive predictive value (96%, 95%, and 98%, respectively) and specificity (96%, 96%, and 99%, respectively). However, both negative predictive value (90%, 88%, and 95%, respectively) and sensitivity (88%, 85%, and 94%, respectively) were lower for 3D ultrasound and ultrasound ellipsoid compared with MRI ellipsoid. An average ultrasound kidney length >16.5 cm was highly predictive of Mayo Clinic imaging classes 1C-1E only in patients aged ≤45 years. CONCLUSIONS: Total kidney volume measurements in autosomal dominant polycystic kidney disease by 3D ultrasound and ultrasound ellipsoid displayed similar bias and variability and are less accurate than MRI ellipsoid. Prediction of high-risk Mayo Clinic imaging classes (1C-1E) by all three methods provides high positive predictive value, but ultrasound ellipsoid is simpler to use and more readily available.


Assuntos
Rim Policístico Autossômico Dominante , Humanos , Rim/diagnóstico por imagem , Rim/patologia , Imageamento por Ressonância Magnética/métodos , Rim Policístico Autossômico Dominante/diagnóstico por imagem , Rim Policístico Autossômico Dominante/patologia , Estudos Prospectivos , Ultrassonografia
4.
Radiology ; 303(1): 11-25, 2022 04.
Artigo em Inglês | MEDLINE | ID: mdl-35191740

RESUMO

Contrast-enhanced US (CEUS) has an important role as a supplement to CT or MRI in clinical practice. The main established utilizations are in the liver and the kidney. The primary advantages of CEUS compared with contrast-enhanced CT or MRI relate to its superior contrast resolution, real-time continuous scanning, pure intravascular nature, portability, and safety-especially in patients with renal impairment or CT or MRI contrast agent allergy. This article focuses on the use of CEUS in the liver and kidney.


Assuntos
Meios de Contraste , Neoplasias Hepáticas , Abdome , Humanos , Rim/diagnóstico por imagem , Fígado/diagnóstico por imagem , Ultrassonografia
5.
Eur Radiol ; 31(11): 8468-8477, 2021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-33912992

RESUMO

OBJECTIVES: To investigate accuracy of contrast-enhanced ultrasound (CEUS) to characterize indeterminate small solid renal masses (sSRMs), excluding lipid-rich AMLs, and cystic renal masses (CRMs) according to the proposed Bosniak Classification 2019 MATERIALS AND METHODS: CEUS of pathology-proven CRMs and sSRMs (without definite enhancement or macroscopic fat on CT/MRI), and CRMs with ≥18 months follow-up were retrospectively reviewed. Two radiologists blindly categorized CRMs according to new Bosniak Classification on CT/MRI. On CEUS, two other radiologists evaluated arterial-phase enhancement of sSRMs relative to renal cortex and categorized CRMs following new Bosniak Classification. Fisher's exact/chi-squared test was used to compare categorical variables, and Cohen κ statistics for inter-observer agreement RESULTS: A total of 237 patients had 241 lesions: 161 pathology-proven sSRMs (122 malignant and 39 benign), 29 pathology-proven CRMs, 51 CRMs with adequate follow-up. Arterial-phase enhancement < renal cortex predicted malignancy with specificity of 97.4% (38/39) (CI 85.6-99.9%), and positive predictive value (PPV) of 98.2% (54/55) (CI 90.4-99.9%). Inter-observer kappa was 0.95. In pathology-proven CRMS, sensitivity of CEUS vs CT/MRI was 100% (15/15) (CI 79.6-100%) vs 60% (9/15) (CI 35.8-80.1%) (p value = .002) and negative predictive value (NPV) 100% (2/2) (CI 17.8-100%) vs 25% (2/8 ) (CI 4.4-59.1%) (p value < 0.0001), with similar specificity (50%) and PPV- 88.2% (15/17) (CI 65.7-97.9%) vs 81.8% (9/11) (CI 52.3-96.8%) ( p value = 0.586). Bosniak Classification inter-observer kappa was 0.92 for CEUS vs 0.68 for CT/MRI (p value = 0.009). CONCLUSION: In our cohort, CEUS had high specificity and PPV to diagnose RCC in sSRMs excluding lipid-rich AML. CEUS had significantly higher sensitivity/NPV to diagnose malignancy in CRMs as compared to CT/MRI. KEY POINTS: • Once lipid-rich AML is excluded by the other modalities, sSRM arterial phase hypo-enhancement relative to renal cortex on CEUS yielded high specificity (97.4%) and PPV (98.2%) to diagnose RCC. • When applying the proposed Bosniak Classification 2019, CEUS showed higher sensitivity compared to CT/MRI (100% vs 60%), p value=.0024, in the stratification of cystic renal masses to diagnose malignancy. • CEUS may reduce the number of CT/MRI Bosniak IIF lesions by assigning them to either II or III/IV categories.


Assuntos
Doenças Renais Císticas , Neoplasias Renais , Meios de Contraste , Humanos , Doenças Renais Císticas/diagnóstico por imagem , Neoplasias Renais/diagnóstico por imagem , Estudos Retrospectivos , Medição de Risco , Tomografia Computadorizada por Raios X , Ultrassonografia
6.
J Obstet Gynaecol Can ; 43(9): 1055-1061, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-33358971

RESUMO

OBJECTIVE: To evaluate the current ultrasound diagnostic criteria for non-viable pregnancy in the first trimester. METHODS: We conducted a retrospective chart review involving 3 tertiary care institutions. Consecutive first-trimester ultrasound reports between January 2013 and June 2016 were reviewed. All first-trimester ultrasound examinations performed to assess pregnancy viability with adequate imaging or clinical follow-up were included. Inclusion criteria based on follow-up were adequate imaging to document ongoing intrauterine pregnancy or clinical follow-up demonstrating viability or non-viability. Data on mean sac diameter (MSD), yolk sac presence/diameter, embryo presence/length, presence of a heartbeat, and heart rate were collected. This was followed by a retrospective validation review of another consecutive cohort. RESULTS: Two hundred and forty-five examinations with a viable-pregnancy outcome and 301 examinations with a non-viable pregnancy outcome were reviewed. The main predictor of non-viable pregnancy was an MSD of ≥20 mm in the absence of a yolk sac (positive predictive value [PPV] 100%; 95% CI 93%-100%), embryo (PPV 100%; 95% CI 90%-100%), or heartbeat (PPV 100%; 95% CI 96%-100%]). Other predictors of non-viability were a measurable embryo without a yolk sac (PPV 100%; 95% CI 91%-100%), yolk sac diameter ≥8 mm (PPV 100%; 95% CI 91%-100%), and absence of heartbeat with an embryo ≥3 mm (PPV 100%; 95% CI 97%-100%). These findings were confirmed in a validation cohort of 45 viable and 53 non-viable pregnancies, with the exception of 1 case of viable pregnancy with no heartbeat and an embryo length 3.3 mm. Based on the median daily growth of 1.2 mm in the viable cohort, 21% of follow-up ultrasound examinations were performed too early for an MSD threshold of 20 mm and 55%, for an MSD threshold of 25 mm. CONCLUSION: In our cohort, MSD ≥20 mm in the absence of yolk sac or an embryo with heartbeat always predicted a non-viable pregnancy.


Assuntos
Resultado da Gravidez , Ultrassonografia Pré-Natal , Feminino , Seguimentos , Humanos , Gravidez , Primeiro Trimestre da Gravidez , Terceiro Trimestre da Gravidez , Estudos Prospectivos , Estudos Retrospectivos , Saco Vitelino/diagnóstico por imagem
8.
CMAJ Open ; 8(3): E506-E513, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32792350

RESUMO

BACKGROUND: Uterine fibroids are common in women and their management is heavily influenced by information gathered through imaging. We aimed to evaluate the type and quality of imaging performed for assessment of uterine fibroids in Canada. METHODS: Starting in July 2015, premenopausal women with symptomatic fibroids were enrolled in a prospective, noninterventional, observational registry (Canadian Women With Uterine Fibroids Registry [CAPTURE]) that included 19 Canadian sites. Clinical characteristics were extracted from the baseline visit. We evaluated the association between demographic and clinical variables of interest with regard to imaging type using unadjusted and adjusted logistic regression models. RESULTS: Of 1493 women, 1148 had ultrasonography, 135 had magnetic resonance imaging (MRI), 80 had other types of imaging and 130 did not have imaging reported within 12 months of the baseline visit. After adjusting for demographic and clinical characteristics, patients who underwent MRI had larger fibroids (odds ratio [OR] per 1-cm increase 1.11, 95% confidence interval [CI] 1.05-1.17) and more numerous fibroids (1 v. > 1; OR 1.74, 95% CI 1.14-2.64) compared with those who underwent ultrasonography only. For ultrasonography reporting, quality criteria were met for 268 of 1148 patients (23.3%). There was a difference in the quality of reporting among the 19 sites (p < 0.001). Logistic regression model accounting for within-site variability showed that reporting results from ultrasonography in the province of Quebec were less likely to meet all quality criteria (OR 0.20, 95% CI 0.06-0.66) and those from sites in more populated cities (≥ 400 000 inhabitants) were more likely to do so (OR 6.15, 95% CI 2.20-17.18). INTERPRETATION: We determined that imaging modality for fibroids is associated with patient characteristics. The quality of reporting results for ultrasonography of fibroids in Canada falls short of internationally endorsed guidelines and needs improvement. STUDY REGISTRATION: ClinicalTrials.gov, no. NCT02580578.


Assuntos
Confiabilidade dos Dados , Leiomioma/diagnóstico por imagem , Sistema de Registros , Neoplasias Uterinas/diagnóstico por imagem , Adulto , Atenção à Saúde , Feminino , Humanos , Leiomioma/epidemiologia , Modelos Logísticos , Imageamento por Ressonância Magnética/métodos , Pessoa de Meia-Idade , Prevalência , Estudos Prospectivos , Quebeque/epidemiologia , Radiologistas , Ultrassonografia/métodos , Neoplasias Uterinas/epidemiologia
9.
Can Assoc Radiol J ; 70(4): 434-440, 2019 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-31585824

RESUMO

PURPOSE: To determine negative predictive value (NPV) of contrast-enhanced ultrasound (CEUS) to demonstrate local tumour progression (LTP) at thermal ablation (TA) sites. METHODS: Our institutional review board approved this retrospective study; acquisition of consent was waived. Consecutive CEUS examinations performed between 2004-2014 for TA site evaluation on patients who could not undergo enhanced computed tomography (CT) or magnetic resonance imaging (MRI), or had inconclusive CT or MRI, were retrospectively reviewed. Those reported as no abnormal enhancement in or surrounding TA site were included. CEUS examination was considered true-negative based on stability or lack of enhancement/washout on follow-up imaging for at least 1 year, and false-negative (FN), if there was an arterially enhancing focus with wash-out at or surrounding TA site on subsequent follow-up imaging. RESULTS: Study population included 56 tumours in 54 patients, 11 women, 43 men; mean age 71 years. Two patients had TA of two different hepatocellular carcinomas. Thirty-six examinations were for hepatic TA and twenty for renal TA. Lesion sizes ranged from 1 cm to 7 cm (mean 3.1 ± 1.2). Mean diameter of 7 recurrences was 13.8 mm. Overall FN rate was 12.5% (7/56). Corresponding numbers were 0% (0/20) for renal TA and 19.4% (7/36) for hepatic TA. Overall NPV of CEUS was 87.5% (49/56) (confidence interval [CI]: 78.8%-96.2%). NPV for renal TA was 100% (20/20) (CI: 100%-100%) and for hepatic TA 81.5% (29/36) (CI: 67.6 %-93.5%). CONCLUSION: In this cohort, CEUS showed high NPV for exclusion of LTP at renal TA sites. NPV for hepatic TA sites was high but lower than renal TA.


Assuntos
Neoplasias Renais/diagnóstico por imagem , Neoplasias Hepáticas/diagnóstico por imagem , Ultrassonografia/métodos , Idoso , Idoso de 80 Anos ou mais , Ablação por Cateter , Meios de Contraste , Progressão da Doença , Feminino , Seguimentos , Humanos , Neoplasias Renais/patologia , Neoplasias Renais/cirurgia , Neoplasias Hepáticas/patologia , Neoplasias Hepáticas/cirurgia , Estudos Longitudinais , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Retrospectivos
10.
Semin Ultrasound CT MR ; 40(4): 358-363, 2019 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-31375175

RESUMO

The coexistence of endometrial adenocarcinoma and adenomyosis in the same uterus is a common phenomenon. In many of such affected patients foci of adenomyosis could also be colonized by adenocarcinoma. The various permutations arising from these scenarios pose preoperative imaging and postoperative pathologic staging challenges. This article aims to raise awareness of these staging issues and lists some of the relevant practical approaches. Adenomyosis reduces the accuracy of magnetic resonance imaging in assessing the depth of invasion as it reduces the contrast between the endometrial cancer adenomyosis-involved myometrium. The article also offers an alternate argument for staging cancers where myoinvasion is found deep in the myometrium, arising from cancer-positive adenomyotic foci when the surface tumor is either limited to the endometrium or to the inner half of myometrium.


Assuntos
Adenomiose/diagnóstico por imagem , Adenomiose/patologia , Neoplasias do Endométrio/diagnóstico por imagem , Neoplasias do Endométrio/patologia , Imageamento por Ressonância Magnética/métodos , Endométrio/diagnóstico por imagem , Endométrio/patologia , Feminino , Humanos , Estadiamento de Neoplasias
11.
J Clin Ultrasound ; 47(8): 453-460, 2019 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-31343081

RESUMO

PURPOSE: The aim is to investigate whether baseline contrast-enhanced ultrasound (CEUS) correlates with indices of activity in Crohn's disease (CD) and can predict response to medical treatment. METHODS: In this prospective study, symptomatic CD patients underwent baseline CEUS performed with Definity using both bolus and infusion methods. Time-intensity curves (TIC), peak intensity (PI), and area under curve (AUC) from a region of interest over the diseased bowel were calculated for both bolus and infusion acquisitions. We used Mann-Whitney U test for continuous and chi-square/two-tailed Fisher's exact test for categorical variable comparison and Spearman's correlation coefficient to correlate clinical score and CEUS kinetic parameters. RESULTS: Twenty-one patients (9 men, 12 women, median age 32 years) were accrued. Fifteen patients had clinically active disease defined as Harvey-Bradshaw Index (HBI) score ≥5. Median values of baseline CEUS parameters PI (bolus: 26 vs 8.86; P = .023 and perfusion: 7.6 vs 3.2; P = .009) and AUC (bolus: 769 vs 248.8; P = .036 and perfusion: 188.9 vs 73.9; P = .012) differed significantly in patients with active vs inactive disease. Nine patients with active disease underwent escalated or new treatment. Five were nonresponders. Responders had higher median values of baseline parameters (PI, bolus: 35 vs 18.8; P = .556, and perfusion: 7.6 vs 3.9; P = 190), (AUC, bolus: 1473.9 vs 314; P = .111, and perfusion: 154.7 vs 74.4, P = .286). CONCLUSIONS: CEUS kinetic parameters correlate with clinical and laboratory indices and are significantly higher in patients with active disease. The responders had higher CEUS kinetic parameters than nonresponders that did not reach statistical significance in our small cohort.


Assuntos
Colo/irrigação sanguínea , Meios de Contraste/farmacologia , Doença de Crohn/diagnóstico , Fluxo Sanguíneo Regional/fisiologia , Ultrassonografia Doppler em Cores/métodos , Adulto , Colo/diagnóstico por imagem , Doença de Crohn/fisiopatologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Adulto Jovem
12.
Radiology ; 292(1): 15-24, 2019 07.
Artigo em Inglês | MEDLINE | ID: mdl-31135294

RESUMO

Imaging plays a central role in the 2018 International Federation of Gynecology and Obstetrics staging system for uterine cervical cancer. The revision calls for a more precise measurement of primary tumor size, best assessed with imaging. Evaluation for abdominopelvic retroperitoneal lymphadenopathy, either with imaging alone or with pathologic analysis, is now also part of staging. Choice of modality depends on the technology available within the practice setting. In high-resource settings, pelvic MRI (to assess tumor size and central pelvic spread) and torso fluorodeoxyglucose PET/CT (to assess lymphadenopathy and distant metastases) are used to assign stage and to plan therapy. In lower-resource settings, analogous modalities are pelvic US and chest radiography. Although imaging is already a part of pretreatment planning in some high-resource settings, its incorporation into assigning stage is a new development.


Assuntos
Fluordesoxiglucose F18 , Imageamento por Ressonância Magnética/métodos , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Compostos Radiofarmacêuticos , Neoplasias do Colo do Útero/diagnóstico por imagem , Neoplasias do Colo do Útero/patologia , Colo do Útero/diagnóstico por imagem , Colo do Útero/patologia , Feminino , Humanos , Estadiamento de Neoplasias , Sociedades Médicas
13.
J Am Coll Radiol ; 16(5S): S77-S93, 2019 May.
Artigo em Inglês | MEDLINE | ID: mdl-31054761

RESUMO

There are approximately 9.1 pelvic surgeries performed for every histologically confirmed adnexal malignancy in the United States, compared to 2.3 surgeries per malignancy (in oncology centers) and 5.9 surgeries per malignancy (in other centers) in Europe. An important prognostic factor in the long-term survival in patients with ovarian malignancy is the initial management by a gynecological oncologist. With high accuracy of imaging for adnexal mass characterization and consequent appropriate triage to subspecialty referral, the better use of gynecologic oncology can improve treatment outcomes. Ultrasound, including transabdominal, transvaginal, and duplex ultrasound, combined with MRI with contrast can diagnose adnexal masses as benign with specific features (ie, functional masses, dermoid, endometrioma, fibroma, pedunculated fibroid, hydrosalpinx, peritoneal inclusion cyst, Tarlov cyst), malignant, or indeterminate. The American College of Radiology Appropriateness Criteria are evidence-based guidelines for specific clinical conditions that are reviewed annually by a multidisciplinary expert panel. The guideline development and revision include an extensive analysis of current medical literature from peer reviewed journals and the application of well-established methodologies (RAND/UCLA Appropriateness Method and Grading of Recommendations Assessment, Development, and Evaluation or GRADE) to rate the appropriateness of imaging and treatment procedures for specific clinical scenarios. In those instances where evidence is lacking or equivocal, expert opinion may supplement the available evidence to recommend imaging or treatment.


Assuntos
Doenças dos Anexos/diagnóstico por imagem , Neoplasias Ovarianas/diagnóstico por imagem , Meios de Contraste , Diagnóstico Diferencial , Medicina Baseada em Evidências , Feminino , Humanos , Sociedades Médicas , Estados Unidos
14.
J Ultrasound Med ; 38(7): 1739-1745, 2019 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-30536401

RESUMO

OBJECTIVES: The purpose of this study was to compare the reliability and agreement of 2 methods of 2-dimensional (2D) shear wave elastography (SWE) on liver stiffness in healthy volunteers. We also assessed effects of the prandial state and operator experience on measurements. METHODS: Two operators, 1 experienced and 1 novice, independently examined 20 healthy volunteers with 2D SWE on 2 ultrasound machines (Aixplorer [SuperSonic Imagine, Aix-en-Provence, France] and Aplio 500 [Canon Medical Systems Corporation, Otawara, Japan]). Volunteers were scanned 8 times by the operators using both machines in fasting and postprandial states. Agreement was evaluated by a Bland-Altman analysis, and the correlation was assessed by the Pearson correlation and intraclass correlation coefficients (ICCs). An analysis of variance was conducted to determine the contribution of the machine, prandial state, and operator experience to the variability. RESULTS: Agreement assessed by Bland-Altman plots showed no statistically significant difference in measured liver stiffness between the machines (mean difference, -0.8%; 95% confidence interval, -3.7%, 2.1%), with a critical difference of 1.36 kPa. The correlation was good to excellent for both the crude overall Pearson coefficient and the ICC, both measuring 0.88 (95% confidence interval, 0.82, 0.92). Subclass ICCs for the fasting state, postprandial state, novice operator, and experienced operator were 0.89, 0.88, 0.90, and 0.86, respectively. The 2-way mixed effect analysis of variance showed that the volunteers accounted for 86.3% of variation in median liver stiffness, with no statistically significant contribution from operator experience, the prandial state, or the machine (P = .108, .067, and .296, respectively). CONCLUSIONS: Our study showed that the 2D SWE techniques had a high degree of reliability and agreement in measurement of liver stiffness in a healthy population. Operator experience and the prandial state did not impart significant variability to stiffness measurements.


Assuntos
Técnicas de Imagem por Elasticidade/métodos , Jejum , Fígado/diagnóstico por imagem , Período Pós-Prandial , Adulto , Feminino , Voluntários Saudáveis , Humanos , Masculino , Reprodutibilidade dos Testes
15.
Radiographics ; 38(5): 1454-1477, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30059274

RESUMO

Contrast material-enhanced US is recognized increasingly as a useful tool in a wide variety of hepatic and nonhepatic applications. The modality recently was approved for limited use for liver indications in adult and pediatric patients in the United States. Contrast-enhanced US uses microbubbles of gas injected intravenously as a contrast agent to demonstrate blood flow and tissue perfusion. The growing worldwide application of contrast-enhanced US in multiple organ systems is due largely to its advantages, including high contrast resolution (sensitivity to the contrast agent), real-time imaging, lack of nephrotoxicity, the purely intravascular property of microbubble contrast agents that allows the use of disruption-replenishment techniques, and repeatability during the same examination. Through illustrative cases, common useful clinical scenarios are discussed, including characterization of liver and renal masses, especially indeterminate lesions at CT or MRI; differentiation of neoplastic cysts from nonneoplastic cysts in various organs; differentiation of tumor thrombus from bland thrombus; and assessment after a renal transplant or local ablative therapy. Common applications in the biliary system, pancreas, spleen, and vasculature also are introduced. Successful routine use of contrast-enhanced US requires an efficient setup and workflow and a thorough understanding of appropriate clinical indications and its advantages that provide added value after CT and MRI. This article familiarizes radiologists with common abdominal applications of contrast-enhanced US and guides them to implement contrast-enhanced US successfully in their clinical practice. Online supplemental material is available for this article. ©RSNA, 2018.


Assuntos
Abdome/diagnóstico por imagem , Meios de Contraste/administração & dosagem , Ultrassonografia/métodos , Doenças do Sistema Digestório/diagnóstico por imagem , Humanos , Doenças Urológicas/diagnóstico por imagem
16.
Can Assoc Radiol J ; 69(3): 311-315, 2018 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-29958834

RESUMO

PURPOSE: The study sought determine effect of requisition timing on the initial-choice imaging modality in appendicitis evaluation. METHODS: This was an institutional review board-approved retrospective study, encompassing 3 University of Toronto teaching hospitals, offering 24/7 radiology coverage. All surgically proven appendicitis cases, from 2012-2014, were included and presurgical ultrasound (US) or computed tomography (CT) reports were analysed. Examinations were all requested by the emergency department, performed by the same technologists and reviewed or finalized by the same radiology group (residents fellows or attending). Two coverage categories, namely regular hours (8 am-5 pm, Monday-Friday) or after hours (5 pm-8 am, Monday-Friday and weekends) were compared. The percentage of the starting modality (US or CT), the rate of CT following an indeterminate US, and the sensitivity of each modality was compared between the 2 categories, utilising Mann-Whitney U and chi-square tests. RESULTS: Presurgical US or CT studies of 494 patients, from February 2012-August 2014, were evaluated. Regular-hours and after-hours coverage demonstrated 174 (89:85 women:men) and 320 (141:179 women:men; P < .04) patients. The average age, 37.9 ± 17.1 women versus 35.2 ± 13.7 men was not statistically different (P = .8). Regular hours included 89 of 174 (51.1%) of US-only examinations, 50 of 174 (29%) of CT-only examinations, and 35 of 174 (20%) of US examinations followed by CT examinations. After hours included 147 of 320 (46%) of US-only examinations, 147 of 320 (46%) of CT-only examinations, and 26 of 320 (8%) of US examinations followed by CT examinations (P < .001). The total diagnostic sensitivities for US and CT were 86% (81% regular hours, 90% after hours; P = .041) and 99.2% (100% regular hours, 99% after hours; P > .05), respectively. CONCLUSIONS: US was less utilised in acute appendicitis detection after hours, although its diagnostic sensitivity was better than regular-hours coverage.


Assuntos
Apendicite/diagnóstico por imagem , Admissão e Escalonamento de Pessoal/estatística & dados numéricos , Tomografia Computadorizada por Raios X , Ultrassonografia , Doença Aguda , Adulto , Feminino , Hospitais de Ensino , Humanos , Masculino , Estudos Retrospectivos , Fatores de Tempo
18.
J Ultrasound Med ; 37(12): 2935-2942, 2018 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-29761521

RESUMO

OBJECTIVES: To determine the negative predictive value (NPV) of contrast-enhanced ultrasound (CEUS) to establish the lack of vascularity in a mass. METHODS: This work was an Institutional Review Board-approved, Health Insurance Portability and Accountability Act-compliant retrospective study. Acquisition of consent was waived. We included all CEUS examinations performed for tissue characterization between 2004 and 2014 that reported showing no vascularity in a mass. Contrast-enhanced ultrasound findings were considered true-negative when there was stability on imaging for at least 1 year or no evidence of a solid mass, if biopsied, and false-negative if there was lesion growth on imaging within 12 months or an indication of a solid mass on the pathologic examination, if biopsied. One author reviewed all of the reports and follow-up examinations. We conducted a consensus review of all false-negative findings mixed with an equal number of true-negative findings by 2 reviewers, who were blinded to the final results. RESULTS: The study population consisted of 97 CEUS examinations in 97 patients, including 48 women and 49 men (mean age ± SD, 65 ± 14 years). Examinations were performed for lesion characterization in the liver (n = 23), pancreas (n = 17), kidney (n = 54), 1 gallbladder, 1 adnexa, and 1 peritoneal lesion. The overall false-negative rate on the official prospective review was 2% (2 of 97). Two false-negative findings were correctly identified on the consensus review. The NPV of CEUS was 97.9% (95 of 97; 95% confidence interval, 93%- 99%) on the official review. CONCLUSIONS: Contrast-enhanced ultrasound has a very high NPV to exclude the presence of flow in a mass, and it can be used to exclude the presence of a solid mass.


Assuntos
Meios de Contraste , Aumento da Imagem/métodos , Neoplasias/irrigação sanguínea , Neoplasias/diagnóstico por imagem , Adulto , Idoso , Idoso de 80 Anos ou mais , Diagnóstico Diferencial , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Estudos Retrospectivos , Ultrassonografia/métodos
19.
J Am Coll Radiol ; 15(5S): S198-S207, 2018 May.
Artigo em Inglês | MEDLINE | ID: mdl-29724422

RESUMO

In the management of epithelial ovarian cancers, imaging is used for cancer detection and staging, both before and after initial treatment. The decision of whether to pursue initial cytoreductive surgery for ovarian cancer depends in part on accurate staging. Contrast-enhanced CT of the abdomen and pelvis (and chest where indicated) is the current imaging modality of choice for the initial staging evaluation of ovarian cancer. Fluorine-18-2-fluoro-2-deoxy-d-glucose PET/CT and MRI may be appropriate for problem-solving purposes, particularly when lesions are present on CT but considered indeterminate. In patients who achieve remission, clinical suspicion for relapse after treatment prompts imaging evaluation for recurrence. Contrast-enhanced CT is the modality of choice to assess the extent of recurrent disease, and fluorine-18-2-fluoro-2-deoxy-d-glucose PET/CT is also usually appropriate, as small metastatic foci may be identified. If imaging or clinical examination confirms a recurrence, the extent of disease and timing of disease recurrence then determines the choice of treatments, including surgery, chemotherapy, and radiation therapy. The American College of Radiology Appropriateness Criteria are evidence-based guidelines for specific clinical conditions that are reviewed annually by a multidisciplinary expert panel. The guideline development and revision include an extensive analysis of current medical literature from peer reviewed journals and the application of well-established methodologies (RAND/UCLA Appropriateness Method and Grading of Recommendations Assessment, Development, and Evaluation or GRADE) to rate the appropriateness of imaging and treatment procedures for specific clinical scenarios. In those instances where evidence is lacking or equivocal, expert opinion may supplement the available evidence to recommend imaging or treatment.


Assuntos
Neoplasias Ovarianas/diagnóstico por imagem , Neoplasias Ovarianas/patologia , Neoplasias Ovarianas/terapia , Meios de Contraste , Medicina Baseada em Evidências , Feminino , Humanos , Recidiva Local de Neoplasia/diagnóstico por imagem , Recidiva Local de Neoplasia/patologia , Recidiva Local de Neoplasia/terapia , Estadiamento de Neoplasias , Sociedades Médicas , Estados Unidos
20.
J Clin Ultrasound ; 46(5): 311-318, 2018 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-29508406

RESUMO

OBJECTIVE: To determine the accuracy of shear-wave elastography (SWE) to differentiate low from advanced degrees of liver fibrosis in hepatitis C patients. MATERIAL & METHOD: Consented native/transplant hepatitis C patients underwent SWE using a C1-6 MHz transducer before ultrasound (US)-guided liver biopsy. Five interpretable SWE samples were obtained from the right lobe of the liver immediately before US-guided random biopsy of the right lobe. Average kilopascal (kPa) values were compared to the meta-analysis of histological data in viral hepatitis (METAVIR) fibrosis grading. SWE values were correlated with the degree of inflammation and fatty infiltration. RESULTS: Study population consisted of 115 patients (63 with transplant, and 52 with native liver) including 29 women and 86 men, with a mean ± SD age of 56 ± 8.7 years. Mean ± SD SWE values were 7.9 ± 3 kPa in 83 patients with METAVIR scores of 0-2 and 13.2 ± 5.9 kPa in 32 patients with METAVIR scores of 3 or 4 (P < .001). Area under curve (AUC) of a Receiver Operating Characteristics curve for advanced degrees of fibrosis was 0.81 (95% CI: 0.71, 0.90) (P < .001). AUCs of transplant versus native livers (0.78 [CI:0.62, 0.94] versus 0.85 [CI: 0.73, 0.96]), degree of inflammation (0.81 [CI: 0.65, 0.97] versus 0.72 [0.56, 0.88]), or degree of fat deposition (0.81 [CI:0.70, 0.92] versus 0.80 [CI:0.61, 1]) were not statistically different (P > .05). for kPa threshold of SWE value of 10.67 kPa to differentiate advanced from low degree of fibrosis had a sensitivity of 59% (CI: 41%-76%) and specificity of 90% (CI: 82%-96%). CONCLUSION: Liver stiffness evaluated by SWE can differentiate low from advanced liver fibrosis.


Assuntos
Técnicas de Imagem por Elasticidade/métodos , Hepatite C/complicações , Hepatite C/diagnóstico por imagem , Cirrose Hepática/complicações , Cirrose Hepática/diagnóstico por imagem , Transplante de Fígado , Diagnóstico Diferencial , Feminino , Hepatite C/patologia , Humanos , Fígado/diagnóstico por imagem , Fígado/microbiologia , Cirrose Hepática/patologia , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Índice de Gravidade de Doença
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...